1. Fasten the control module on the control module holder with the four fastening screws.

Tightening torque: 10 Nm (7.5 ftlb.).

2. Push in connectors -B- on the DME control module and close the latching lever -4- until the lever engages.
3. Press in connectors -A- on the control module, until the connectors engage.

4. Turn the control module holder -3- and push it in under the fastening nut -2-. Tighten both fastening screws -1- and the fastening nut -2-.

Tightening torque: 10 Nm (7.5 ftlb.).

5. Place carpet lining in position, paying attention to the fitted shape.
6. Program the DME control module with the Porsche System Tester. Refer to "Programming new DME control module" and "Programming DME

control module".

Programming new DME control module.

NOTE:

-

If a new DME control module is to be installed in a vehicle, the DME code specified in IPAS and the immobilizer code must be entered in the
DME control module.

-

You can get the codes from IPAS or from your importer by specifying the vehicle identification number.

-

During DME programming, it is essential to guarantee the power supply for the Porsche System Tester. In case of doubt, connect a charging unit
to the vehicle battery.

-

Symbol for the TAB key = [->|]

-

The instructions of the Porsche System Tester have highest priority.

-

The procedure listed has been structured generally, changes or additions can be made.

1. Connect the Porsche System Tester to the vehicle and start the System Tester. Switch ignition on.
2. Select vehicle type using the cursor keys. In the 911 Carrera - 911(996).

Version 1:
-

Using the [->|] key, move from the vehicle type to the list of control modules.

Version 2:
-

Using the [>>] key, move from the vehicle type to the list of control modules. The Vehicle Ident. No. under point 7 only has to be confirmed
and not entered.

3. Select DME with the cursor keys and press the [>>] key.

DME Control Unit As of ME 7.2|Page 2951 > < DME Control Unit As of ME 7.2