porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

DME Control Unit As of ME 7.2|Page 2610 > < DME Control Unit As of ME 7.2|Page 2608
Page 2
background image

14. The following message appears on the screen: "Please confirm input" 

Confirm input with the [F7] key.

15. The following message appears on the screen: "Input new immobilizer code" 

Input immobilizer code and press the double arrow key [>>].

16. The following message appears on the screen: "Please confirm input" 

Confirm input with the [F7] key.

17. The following message appears on the screen: "Select data record" Select data record according to the allocation table and press the double arrow

key [>>].

The control module will now be programmed. Programming will take approx. 5 minutes.

WARNING:  Never interrupt the programming process

18. The following message will appear after the programming time has elapsed: "Programming was completed successfully" Press the double arrow

key [>>], switch the ignition off and then on again.

This completes programming of the DME control module.

Allocation table

NOTE:  The DME control module can also be reprogrammed using the Porsche System Tester 2.

In this case, the old data record will be overwritten by a new record (e.g. RoW instead of Germany)

Program map/data must be selected in Step 7 if reprogramming is necessary.

WARNING:  Risk of damage if allocation is incorrect

-

Ensure correct allocation of the data record in the control module to the installed catalytic converter (refer to the allocation table)

DME Control Unit As of ME 7.2|Page 2610 > < DME Control Unit As of ME 7.2|Page 2608