porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Connecting Rod, Engine > < Tools - Calibration Gauge for Special Tool 9201
Page 2
background image

2.

Apply gauge block 9201/2, making sure bearing foot is centered on slides.

3.

Perform checking procedure as when applied on a toothed belt, i.e. press in measuring point slowly until lockpin is felt to engage and read
displayed value on dial gauge.

Note:

Older slides could be drilled slightly off-center. When measuring in this case there could be different displayed values depending on the position
of the slides.

Therefore, measuring with the gauge should be repeated with the slides in different position. Find the position, which is closest to an adjusting value of
40 scale units. Mark slides (e.g. with paint or electric inscriber) and perform calibration as well as all future measurements in this position.

4.

If the display is not Within the specified value of 40 +/-  3 scale units, adjust the dial-gauge. This is done by turnine the calibration screw with a
small screwdriver until the specified value of 40 scale units is reached. The gauge block 920-1/2 remains between the test sensor of the tester for
this procedure.

5.

Repeat the checking procedure with gauge block 920-1/2 after calibration.

Connecting Rod, Engine > < Tools - Calibration Gauge for Special Tool 9201