porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Coolant Line/Hose|Service and Repair|Page 2100 > < Coolant Line/Hose|Service and Repair
Page 2
background image

flow meter. Reclose the omega clip for the removal (risk of breakage).

-

Unscrew the fastening screw M6 x 34 (a/f 13) at the rear of the air cleaner housing.

6. Before removing or relieving the drive belt, loosen the drive pulley of the hydraulic pump. Unscrew three hexagon-head bolts by approx. 1/4 turn.

7. Relieve drive belt. To do this, turn the tensioning lever of the tensioning roller clockwise with a socket wrench (a/f 15) and hold, remove the belt

from the drive pulleys of the air-conditioning compressor, hydraulic pump and the generator.

Relieving and removing belt.

8. Unscrew the three already loosened fastening screws of the belt pulley and remove the belt pulley from the hydraulic pump.

Coolant Line/Hose|Service and Repair|Page 2100 > < Coolant Line/Hose|Service and Repair