porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Bearing Housing With Intermediate Shaft|Page 1499 > < Bearing Housing With Intermediate Shaft|Page 1497
Page 1
background image

Auxiliary Shaft: Service and Repair
Removing and Installing Bearing Cover For Intermediate Shaft

Removing And Installing Bearing Cover For Intermediate Shaft

CAUTION:

-

Pentosin Is hazardous to the health.

-

Wear protective gloves and goggles. If the eyes or skin come into contact with the fluid, wash immediately with water.

-

Collect emerging Pentosin.

-

Protect the leads against soiling and damage with caps.

-

Clean hoses which come Into contact with Pentosin thoroughly.

-

After removal of the chain tensioner, the crankshaft must not be turned under any circumstances, because otherwise the timing chain may jump
over.

-

Danger of engine damage.

NOTE:

-

As from model year 2002, it will only be possible to remove the bearing cover with the engine installed in manual transmission vehicles.

-

In Tiptronic vehicles, the complete engine/transmission unit must be removed.

Preliminary work

NOTE:

Note the work instructions for disconnecting and reconnecting the battery.

-

Disconnect the battery.

-

Drain engine oil (insert the oil drain plug again with a new aluminium sealing ring and tighten with a tightening torque of 50 Nm (37 ftlb.).

Tiptronic:

-

Remove and install the engine.

-

Remove transmission.

Manual transmission:

-

Remove transmission.

Removing Bearing Cover

1. Remove air cleaner housing (engine installed).
2. In vehicles with air conditioning, the following work steps must be performed on the installed engine:

a. Remove the drive belt from the belt pulley of the air-conditioning compressor. Mark the running direction of the belt with a coloured pen.

Slacken belt by turning the tensioning pulley (wrench size 24) clockwise, hold still and simultaneously take the drive belt off the belt pulley of
the air-conditioning compressor. Carefully allow the tensioning roller to turn back into tensioning position.

Bearing Housing With Intermediate Shaft|Page 1499 > < Bearing Housing With Intermediate Shaft|Page 1497