porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2377 > < Initial Inspection and Diagnostic Overview|Page 2375
Page 5
background image

3. Measure the battery voltage with a hand-held multimeter.

-

The battery open-circuit voltage should not fall below 12.5V.

-

If the hand-held multimeter shows 12.5 V or over, the battery voltage is OK.

-

If the hand-held multimeter shows a battery voltage below 12.5 V:  Charge battery.

Battery Load Test

NOTE:

-

The electrolyte gravity test provides information about the state of the battery in connection with the battery load test.

-

A battery test device is required for the load test. Refer Battery test charge device, Workshop Equipment.

-

The battery must not be removed or disconnected.

-

The battery must be charged before the load test is performed.

Carry out battery load test:

1. Switch ignition off and remove ignition key.
2. Observe the information in the operating instructions of the battery test device.
3. Connect the pliers of the test lines to the battery terminal as described in the operating instructions of the test device.

-

As the load current varies, the current must be set depending on the battery capacity (operating instructions of test device).

The load test currents can also be referred to in the following tables.

4. Carry out the battery load test according to the operating instructions and compare to the test result of the following tables.

-

A minimum voltage is determined by the battery load test depending on the specified battery voltage.

Table:
Battery capacity:...................................................................................................................................................................................................80 Ah
Cooling test current...............................................................................................................................................................................................380 A
Load current..........................................................................................................................................................................................................300 A
Minimum voltage (limit value)................................................................................................................................................................................9.5 v

5. If the minimum voltage is not attained, replace battery.

Remarks on battery load test:

-

The battery voltage sinks during this test due to the severe load on the battery.

-

If the battery is in order, the voltage value only reduces to the minimum voltage.

-

If the battery is faulty, the battery voltage will sink very quickly below the specified minimum voltage.

-

After the test has taken place, the low voltage value remains over a long period of time, the voltage increases again slowly.

Charging Battery

WARNING:

-

The battery plugs must always be screwed in correctly when charging and during the voltage measurement and the load measurement.

-

Rooms in which batteries are being charged, should not be entered with a naked flame or when smoking. Gases form through the charging process
in the batteries which are highly flammable.

NOTE:

-

A battery charging device is required. Refer Battery test charge device, Workshop Equipment.

-

Observe charging device operating instructions.

-

The battery must have a minimum temperature of 10 degree C.

-

Do not charge batteries too quickly if possible as they can be damaged in this way.

-

If totally discharged batteries are charged quickly, they will not take up a charge current or they will be indicated too early as being full by the
so-called "surface charge".

1. Switch off battery charging device.
2. Switch ignition off and remove ignition key.
3. First disconnect the ground strap of the battery, then the positive battery terminal.
4. Connect positive line of the battery charging device to the positive terminal of the battery.
5. Connect negative line of the battery charging device to the negative terminal of the battery.
6. Set the charge current on the battery of the charge device according to the battery capacity.
7. Switch on battery charging device.

Procedure for loading totally discharged batteries:
-

Batteries which are not in operation for a long period of time, discharge.

-

A battery is totally discharged if the open-circuit voltage has sunk below 11.6 V.

-

In totally discharged batteries, the battery acid (sulphuric acid water mixture) consists of virtually only water, as the sulphuric acid proportion

Initial Inspection and Diagnostic Overview|Page 2377 > < Initial Inspection and Diagnostic Overview|Page 2375