Hourmeter - first occurrence.

The value indicates the operating hours at the time the fault first occurred.

Last occurrence (month, day): The date (month and day) on which the fault was last detected is displayed.

Temperature - last occurrence: The value indicates the temperature (temperature sensor in the gateway) at the time the fault was last detected.

The temperature of the fibre optic transmitter (FOT) is monitored: max 85 degrees C.

Supply voltage - last

The value indicates the voltage at the time the fault last occurred.

occurrence.

Hourmeter - last occurrence.

The value indicates the operating hours at the time the fault was last detected.

CDR23

General Information On The Fault Memory

Fault code setting conditions

Fault codes can be set in several circumstances, e.g.

-

battery disconnected

-

plug connections disconnected

-

power failure

In these circumstances, no fault is present in the system and the fault memory must be erased.

Fault memory Info key F8

In order to be able to assess the fault exactly, the fault memory Info key F8 must be pressed. This information should be saved using the Save key F4 and
printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased.

Fault type - Frequency counter/Temperature/Voltage; Speed

Fault type

The display shows whether the fault is.
-

not present

-

present.

Frequency counter

When a fault first occurs, a fault entry with the status present is set in the fault memory and the counter is simultaneously
set to 50.

If a fault is present, the counter is incremented by one whenever the system is booted. The maximum count is 255.

The counter is decremented if the status fault no longer present is entered and the fault does not occur again when the
system is booted. The entry in the fault memory is erased automatically when the counter reaches 0.

If the error occurs again when the counter is between 1 and 49, the counter is reset to 50.

Temperature:

The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The temperature of
the fibre optic transmitter is monitored: max 85 degrees C.

Voltage

The value indicates the voltage at the time the fault occurred.

Vehicle speed:

The value indicates the vehicle speed at the time the fault occurred.

General Information (PCM)

General Information

The PCM is protected against theft by a device code. Furthermore, the integrated navigation system is also protected by a code against unauthorized
users.

Both codes must be input when the system is commissioned at the factory or after replacement of the display and operator control unit and the navigation
unit. In both cases, the code for the PCM must be input first.

Only the NAVI code has to be input again after the navigation system has been exchanged.

Only the PCM code has to be input again after an interruption in the continuous power supply (e.g. when the battery is changed) if both codes were input