911 Targa (996) F6-3.6L (2004)
Cover for magnetic hydraulic valves in installation position with integrated seal
-
1 : Camshaft adjustment valve (control chain side)
-
2 : Valve lift adjustment valve
Tightening torque: 10 Nm (7.5 ft. lbs.)
13. Install ignition coils. Insert three ignition coils in the spark-plug recesses, position and then tighten two M6 x 25 hexagon socket head bolts.
Tightening torque: 10 Nm (7.5 ft. lbs.)
14. Install holder for the main muffler. Insert holder from the clutch side, position two M8 x 30 hexagon-head bolts at the top and two M8 x 25
hexagon-head bolts at the bottom and tighten. Connect the electrical plug of ignition coil cylinder 2 and the two electrical plugs of the magnetic
hydraulic valves, then fasten the cable in the sheetmetal brackets.
Tightening torque: 23 Nm (17 ft. lbs.)
15. Install the shield. Insert the shield, position and tighten the two M6 x 16 hexagon-head bolts.
Tightening torque: 10 Nm (7.5 ft. lbs.)
16. Turn the engine at the assembly support by approximately 90° until the engine is horizontal (intake system at the top).
Tightening torques for installing camshaft