porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Oxygen Sensor|Service Precautions|Page 1760 > < Oxygen Sensor|Service Precautions
Page 1
background image

Oxygen Sensor: Testing and Inspection

Oxygen Sensor Monitoring

Diagnosis of Lambda Sensor Upstream Catalyst

This diagnostic function detects all electrical connection faults of the lambda sensors.

The diagnostic function is performed if:

-

the sensor heating has been switched on for a time longer than its threshold,

-

the temperature of the upstream catalyst exceeds the dew-point,

-

a given period has elapsed,

-

the exhaust gas temperature of upstream catalyst is below its threshold,

-

there is active lambda control.

If the sensor voltage of the upstream catalyst remains within a given voltage range for longer than a given period a wire interruption or defective sensor
heating is assumed.

If the internal resistance of the sensor exceeds threshold while the modeled exhaust gas temperature is greater than its threshold, then a wire interruption
of sensor ground is determined.

If the sensor voltage lies above the threshold for longer than a given period, then a short circuit of the sensor signal wire to battery is assumed.

If the sensor voltage of the downstream catalyst exceeds a threshold and there is active lambda control, switched off secondary air and secondary air
diagnosis, no secondary air system and canister purge system failure, and the sensor voltage of the upstream catalyst remains within the voltage range for
a given period without interruption, a defective sensor with limited voltage amplitude is determined.

If the sensor voltage of the upstream catalyst lies below a threshold and there is active lambda control, switched off secondary air and secondary air
diagnosis, no secondary air system and canister purge system failure without interruption for longer than a given period, and in addition the sensor
voltage of the downstream catalyst exceeds a threshold or if the sensor voltage of the upstream catalyst in case of cold sensor upstream catalyst lies
below a threshold without interruption for longer than a given period, a wire-to-wire short circuit between sensor signal and ground lead is assumed.

If the sensor voltage of the upstream catalyst remains within the correct voltage range and the sensor voltage of the downstream catalyst lies below a
threshold for longer than the a given period, then a short to battery is assumed.

Diagnosis of Lambda Sensor Upstream Catalyst - Part I

Oxygen Sensor|Service Precautions|Page 1760 > < Oxygen Sensor|Service Precautions