Battery charging condition

Spec. gravity in kg/cu.dm

in normal climatic zones
discharge

1.12

half charged

1.20

well charged

1.28

Battery charging condition in

Spec. gravity in kg/cu.dm

tropical climatic zone
(hot countries)
discharge

1.08

discharge

1.08

well charged

1.23

The gravity of electrolyte must be at least 1.24 kg/cu.dm.

-

If the gravity of electrolyte is too low, charge battery.

-

After charging the battery, repeat the gravity of electrolyte test.

The measuring values for the gravity of electrolyte of the individual battery cells should not deviate by more than 0.03 kg/cu.dm from each other.

Example 1: The gravity of electrolyte in cell 4 is too low.

Example 2: The gravity of electrolyte in cells 4 and 5 is too low. The specific gravity of electrolyte deviations between the battery cells is larger than 
0.03 kg/cu.dm.

-

If the nominal values are not achieved, replace battery.

-

If the nominal values are achieved, screw in the original plug again.

Open-circuit voltage measurement

NOTE:  Use a hand-held multimeter to measure the battery voltage.

1. Switch ignition off and remove ignition key.
2. Disconnect ground strap on the battery.

NOTE:  After charging and a waiting time of at least 2 hours during which the battery should neither be burdoned or charged.

3. Measure the battery voltage with a hand-held multimeter.

-

The battery open-circuit voltage should not fall below 12.5V.

-

If the hand-held multimeter shows 12.5V or over, the battery voltage is OK.

-

If the hand-held multimeter shows a battery voltage below 12.5V: charge battery.

Battery load test

NOTE:

-

The gravity of electrolyte test provides information about the state of the battery in connection with the battery load test.

-

A battery test device is required for the load test.

-

The battery must not be removed or disconnected.

-

The battery must be charged before the load test is performed.

Carry out battery load test:

1. Switch ignition off and remove ignition key.
2. Observe the information in the operating instructions of the battery test device.
3. Connect the pliers of the test lines to the battery terminal as described in the operating instructions of the test device.

-

As the load current varies, the current must be set depending on the battery capacity (operating instructions of test device).