14.2. Insert seal into the connector and press down as far as it will go. Check seal is seated properly.
15. Push on connector on triggering unit for airbag -10- until it engages securely and lock it.
Installing wire harness for airbag from the triggering unit to the A-pillar connection point
WARNING: Danger of injury and material damage if airbag units are not handled correctly.
-
Always observe the safety regulations for handling airbag units.
-
Remove ignition key. Disconnect battery. Route or isolate the ground strap so that all contact with a ground carrier (e.g. body, seat frame) is
avoided.
-
After the battery is disconnected, always wait for 1 minute before disconnecting the airbag plugs.
INFORMATION: Allocation of lines.
1. Release and disconnect plug connection for main wire harness to wire harness for door -3 and 4-.
2. Cut and remove tie-wrap for fixing the wire harness to the connector housing.
3. Release cap on both sides -arrow a- and remove from the connector housing.