911 Targa 4S (997) F6-3.8L (2007)
Collecting Pentosin
Dispose of extracted Pentosin according to the relevant regulations. Lay a cloth under the tank to collect any emerging Pentosin.
3. Remove air cleaner housing.
4. Loosen drive belt -1- and remove pulley.
4.1.
Loosen screws -4- on the pulley.
4.2.
Turn the tensioner -3- clockwise at the hexagon (a/f 30) using a ring wrench -2- and take off the belt.
4.3.
Allow the tensioner to slide back to its initial position.
Removing the pulley
5. Remove the resonance tube. This is necessary in order to remove the return line at the hydraulic pump and the rear fastening screw.
Resonance tube mounting
Removing and installing hydraulic pump
Removing hydraulic pump
1. Remove hydraulic pump (hydraulic pump/supply tank assembly).
1.1.
Disconnect pressure line -1- at the hydraulic pump. When detaching the pressure line -1- (a/f 16 mm), counter at the connection piece (a/f 27
mm).