Oxygen Sensor: Description and Operation
Oxygen Sensor

Function of the Oxygen Sensor Diagnosis 

To diagnose the oxygen sensor signals, the Engine Control Module (ECM) uses the form and frequency of the respective signal as a measuring value.
The data to be calculated by the ECM are the time of the sensor voltage between positive and negative limits, the maximum and the minimum
recognized sensor voltage values, oxygen sensor value toward rich, oxygen sensor value toward lean, sensing limits of oxygen sensing, period duration
of sensor ahead of the Three Way Catalytic Converter (TWC), and the sensor voltage ahead of the TWC.

The oxygen sensors are monitored for:

Operational readiness.

Connectivity.

Short circuit to positive.

Short circuit to ECM ground.

Wire break.

Aging of oxygen sensors via the adjustment frequency and adjustment position.

Function 

Determination of Maximal and Minimal Sensor Voltage
After starting the engine, the values for the previous maximum and minimum are erased. During driving, the absolute maximum and minimum is
established, based on for the diagnosis predetermined engine speed and load range. These values are recorded by the ECM. If the sensor voltage is
higher than the presently stored maximum value, it will be overridden by the current sensor voltage. The same applies to the minimal values.

Calculation of the Time Between Positive and Negative Limits:
If the sensor voltage exceeds the sensor limits, the time measurement is started between the positive and negative limits. If the sensor voltage is lower
than the limit range, the time counter is stopped. The time between starting and stopping of the counter is measured.