porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Transfer Case|Service and Repair > < Transfer Casing|Page 1735
Page 1
background image

Transfer Case: Testing and Inspection

Test Conditions:

-

To check, viscous clutch must be at room temperature

-

Test duration approx. 45 seconds (Determine measurement after 20 seconds)

-

Repeat measurement after viscous clutch has cooled off for 1 hour

Procedure

1. Connect System Tester 9288 and select Actual values " menu (ABS speed) (Refer to ABS brakes in Brakes and Traction Control).
2. Place front wheels of vehicle onto brake dynamometer.
3. Switch off engine, engage parking brake and shift transmission into neutral position.
4. When the rollers have started, switch on ignition and press key > of system tester.

-

The tester will then return to the point where diagnosis was interrupted.

5. Set front wheels into motion with dynamometer rollers (max. 5 mph) and determine tractive power of front wheels after 20 seconds.

NOTE:  When measuring the wheels individually, add measurements obtained for both front wheels.

6. The viscous clutch is operative if the tractive power of the front wheels is within the boundary curves on the diagram.

-

The driving speed of the front axle must be taken into account during these measurements (speed can be read off on System Tester 9288).

Example:
At a vehicle speed of 3 mph at the front axle, the tractive power must be between approx. 580 N and 1180 N if the viscous clutch is o.k. (cf.
diagram).