porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Roll Bar|Testing and Inspection|Page 4542 > < Keyless Entry Module|Service and Repair|Page 4538
Page 1
background image

Roll Bar: Testing and Inspection

Checking Roll-Over Protection System

Tools

Preliminary work

1. Fully open the convertible top.

General warning notes

Safety instructions for work on the roll-over protection system

CAUTION:  Danger of injury when working on the roll-over protection system.

-

The movement range of the roll-over protection system must be kept clear.

-

Work on the roll-over protection system must only be performed with the ignition key withdrawn.

-

Attention: Do not begin assembly work until after a waiting time of 1 minute has elapsed.

-

Tools or other objects must not be placed in the extension area of the roll-over protection system.

-

Remove the roll-over bar modules only after the roll-over bar has been extended (triggered).

It is not permissible to perform repairs on the roll-over bar modules.

The roll-over bar modules must be replaced in the event of visible damage or pressure marks.

After assembly work on the roll-over protection system - but at least every 2 years - the function of the roll-over protection system must be tested by
triggering it via the diagnostic interface of the PIWIS tester 9718.

Only perform the function test on the roll-over protection system with the hardtop and cap removed and the convertible top open.

Checking roll-over bar

INFORMATION:  Actuate the roll-over protection system only if:

-

the hardtop is removed

-

the convertible top is open

-

the caps are removed

1. PIWIS Tester 9718 must be connected to the diagnostic socket. Switch on ignition. Select menu item "Airbarg/POSIP", and select menu item

"Drive links" in the command line which then appears, select "Triggering roll-over bar" in the command line that appears. Press the key
combination [F2] and [F8] within 2 s, as described in the Tester; the roll-over protection system is triggered. Please note: time until triggered
approx. 10s.