porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Air Cleaner Housing > < Checking Fuel Pressure|Page 525
Page 4
background image

9. Pour the collected fuel into a suitable measuring container and compare the actual quantity delivered with the required quantity.

-

Required value for quantity of fuel delivered by fuel pump 1:
>> in 30 seconds, at least 1.1 litres << 1)

10. Repeat the process for fuel pump 2 (EKP 2).

10.1. Proceed as described for fuel pump 1: Activate fuel pump relay 2 using the PIWIS Tester 9718.

-

Required value for quantity of fuel delivered by fuel pump 2:
>> in 30 seconds, at least 1.5 litres << 1)

11. Disconnect flat connector with hose and connect the rapid-action coupling to the fuel return line. Make sure the coupling is fitted correctly and

securely (it must click into place) by pulling the line apart.
1) The specified values are minimum quantities. If the supply voltage is significantly higher than 12 volts (e.g. 13.5 volts), the fuel pumps will

deliver more fuel.

Subsequent work

1. Switch off ignition, switch off Porsche System Tester and disconnect adapter line in the passenger compartment.
2. Install the cover for the rear and centre underbody.

Air Cleaner Housing > < Checking Fuel Pressure|Page 525