power to the vehicle.

Both batteries must be 12 V batteries.

The capacity (Ah) of the battery supplying the power must not be significantly lower than that of the flat battery.

The flat battery must be properly connected to the vehicle electrical system.

1. Pull out the power connection -A- on the fuse carrier.

2. First connect the positive cable to the battery, then to the power connection -A- on the fuse carrier.
3. First connect the negative cable to the negative terminal of the battery supplying the power, then to the ground point -B-.
4. Now the servomotors for the front and rear covers can be operated.

Jump lead starting

Both batteries must be 12 V batteries.

The capacity (Ah) of the battery supplying the power must not be significantly lower than that of the flat battery.

The flat battery must be properly connected to the vehicle electrical system.

1. First connect the positive cable to the positive terminal of the recipient battery, then to the positive terminal of the donor battery.
2. First connect the negative cable to the negative terminal of the donor battery, then to a suitable ground point on the recipient car.

A suitable ground point can be e.g. one specially for jump starts, a solid metal component or the engine block. The ground point should be as far
away from the battery as possible.

If a suitable ground point is only present in the donor vehicle, then first connect the negative cable to the negative terminal of the recipient battery
and then to the ground point of the donor vehicle.

If neither vehicle has a ground point, first connect the negative cable to the negative terminal of the donor battery, then carefully to the negative
terminal of the recipient battery.

3. Have the engine of the vehicle supplying the power run at a higher speed.
4. Start engine. Do not spend longer than 15 seconds trying to start the vehicle with the jump leads - after 15 seconds have elapsed, wait for at least

one minute.

Before disconnecting the jump leads, switch on high electrical loads in the recipient vehicle, e.g. rear window heater and interior blower, in order
to reduce any voltage peaks on disconnection. The light must not be turned on.