porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Condenser HVAC > < Procedures|Page 2850
Page 2
background image

1. Check the air gap between the pressure plate and belt pulley with a depth gauge.
2. Place a rule on the outer edge of the belt pulley and use a depth gauge to measure up to the pressure plate.

INFORMATION:
-

Always measure at at least three points on the pressure plate in order to obtain a mean value.

-

Distance: 0.5 mm ± 0.15 mm

3. Apply battery voltage to the magnetic coupling and measure the distance (air gap) to the attracted pressure plate.
4. If the air gap is not in the tolerance range, it must be adjusted with the aid of the spacer washers.

Condenser HVAC > < Procedures|Page 2850