911 Turbo S Cabriolet (996) F6-3.6L Turbo (2005)
Information Bus: Application and ID
Optical Waveguide - MOST Bus
Tools
INFORMATION: The optical waveguide will be used as from model year 2003.
Specifications on handling the optical waveguide
The plug connections must not be connected or disconnected with tools.
The optical waveguide and the plug connections must not be brought into contact with liquids such as water, leakage fluids, preservers, anti-freeze fluids
or cleaning agents. This may impair the function of the MOST system or even complete system failures. Even plug connectors with connected protective
caps must not be brought into contact with the listed liquids.
If the optical contacts, plug connectors or bushings are not connected or the connectors are not equipped with protective caps, all contact with dust and
other materials (lubricants) must be avoided.
The optical contacts, plug connectors or bushings must not be cleaned.
Storage, packaging, transport
The optical waveguides must not be stored in the open air.
The optical waveguides must be protected from direct sunlight when stored.
The optical waveguides must not be exposed to high levels of air humidity when stored. Recommended storage conditions: Temperature - between -20
degrees C and +40 degrees C, air humidity - between 40% and 60%.
The optical waveguides must be stored in cardboard boxes or plastic bags.
No forces may be exerted on the stored optical waveguides which could deform or damage them.
The optical waveguides may only be stored with connected dust protective caps.
During storage, the bending radius of 30 mm must always be maintained.
Optical waveguides with damaged surfaces must be replaced.
Installing optical waveguides in the vehicle
The limit values listed below must not be exceeded when installing an optical waveguide in the vehicle: