Air Door Actuator / Motor: Service and Repair
Ventilation

Removing and installing drive motor for fresh-air/recirculation valve

NOTE:  Remove and install drive motor on installed heating/fresh-air unit.

Removal

1. Press the recirculation button before Removal (fresh-air supply interrupted). The drive motor of the installed heating/freshair unit can be removed

in this position (recirculation).

2. Remove footwell bulkhead and right air guide. Disconnect electrical plug connection of the drive motor and undo fastening screw.
3. Swivel down the drive motor and remove to the side.

NOTE:  If the rotary knob for air distribution is set to Defrost (windscreen) with the recirculation button switched on, the recirculation button is
automatically switched off.

Installation

1. The Removal or Installation position of the drive motor and fresh-air/recirculation valve cannot be changed.
2. Tighten fastening screw carefully, plastic housing.
3. Engage electrical plug connection and route wire carefully.
4. Perform a function test after Installation.