porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Navigation Module|Locations|Page 176 > < Navigation Module|Locations
Page 1
background image

Navigation Module: Adjustments

Adjusting (calibrating) PCM navigation unit

General

The PCM navigation unit must be calibrated after maintenance work or commissioning. Calibration is the prerequisite for exact route guidance.

The following components of the PCM navigation unit must be calibrated or initialised:

-

GPS receiver: After an interruption in the power supply (terminal 30), the installed GPS receiver loses its so-called almanac.
The almanac stores the satellite orbits and ensures fast location of the individual satellites when the system is started.

-

Distance sensor: The distance sensor transmits the distance travelled to the PCM navigation unit. The distance signal changes if the circumference
of the tyre changes (e.g. tyre change). This modification must be calibrated by the PCM navigation unit afterwards.

NOTE:  The distance sensor must be calibrated after commissioning of the PCM navigation unit or after changing a tyre. If a system that has already
been calibrated is disconnected from the power supply (terminal 30), the calibration of the distance sensor is retained.

-

Gyroscope: The gyroscope detects changes in the direction of travel and must be calibrated after commissioning.
The gyroscope shows temperature-dependency. This temperature-dependency is compensated by the system if the "cold" (not calibrated) system is
switched on and left to stand for approx. one hour.

NOTE:  The gyroscope must be calibrated after commissioning only. If a system that has already been calibrated is disconnected from the power supply
(terminal 30), the calibration of the gyroscope is retained.

Procedure after commissioning:

Please observe the sequence!

-

Switch on the PCM with a free panoramic view for approx. 20 minutes (to load GPS almanac).

-

Drive on a motorway if possible at a speed greater than 60 km/h for a distance of approx. 50 km. (calibration of the distance measurement)

-

Drive approx. 10 km in an urban area and take frequent turnoffs. Stop for approx. 10 seconds occasionally. (calibration of the gyroscope)

-

Switch on the PCM navigation unit for approx. one hour with the vehicle horizontal. (temperature compensation of the gyroscope)

Calibration is necessary after the following maintenance work:

-

After changing a tyre

-

After the power supply has been interrupted

Procedure after changing a tyre

-

Drive on a motorway if possible at a speed greater than 60 km/h for a distance of approx. 50 km (Calibration of the distance measurement).

Procedure after the power supply has been interrupted:

-

Switch on the PCM with a free panoramic view for approx. 20 minutes (to load GPS almanac).

Navigation Module|Locations|Page 176 > < Navigation Module|Locations