Boxster (987) F6-2.7L (2006)
Return line at hydraulic pump
3. Connect return line at the supply tank/hydraulic pump.
4. Secure air-conditioning compressor.
Air-conditioning compressor
Tighten screws -2- on air-conditioning compressor.
-
Tightening torque: 23 Nm (17 ftlb.)
5. Install supply tank.
Pay attention to markings on the catch and on the supply tank, see -Arrow-!
Supply tank
6. Connect supply and return line at underbody.
6.1.
Connect supply and return line at underbody.