porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Hydraulic Control Assembly - Antilock Brakes|Service and Repair|Page 2546 > < Hydraulic Control Assembly - Antilock Brakes|Service and Repair|Page 2544
Page 3
background image

After bleeding, check the assignment of the brake lines to the correct brake calipers. Carry out a swap test using the PIWIS Tester.

1. Install hydraulic unit -D-. Observe tightening torques

Hydraulic unit

1.1.

Insert hydraulic unit with support and tighten fastening nuts -arrows- (3-point mount).

1.2.

Connect control unit connector to hydraulic unit and lock it.

1.3.

Fit brake lines -2- in correct position. Observe marking on the hydraulic unit -D- and intermediate piece -E-. RL = rear left/RR = rear right/FR
= front right/FL = front left.

1.4.

Fit the brake lines -1- on the hydraulic unit -D- and then at the correct position on the brake master cylinder. HZ 1 = Brake master cylinder
push-rod circuit (close to fastening flange). HZ 2 = Intermediate piston circuit.

1.5.

Fit the brake line -1- on the hydraulic unit first and then on the brake master cylinder and tighten to 25 Nm/19 ftlb. (increased from 20 Nm/15
ftlb.)
.
When tightening the brake lines -1- on the brake master cylinder (25 Nm/19 ftlb.), use special tool retaining device 9763 to counter at the
crimping point of the hose (close to the rigid line) -3-. This prevents the hoses from twisting away from the new type of brake lines -1- that are
used (modified material at the cap screws/legal requirement).

Brake lines/hydraulic unit

Information: First bleed the brake system in the normal way - with the bleeding device at the reservoir and approx. 2.0 bar pressure (primary
circuit).

Then, use the PIWIS Tester to bleed the brakes as well (secondary circuit). Only necessary if the hydraulic unit was replaced and if brake pedal travel
is excessive after bleeding in the normal way (primary circuit). The process is menu-driven. Always observe the specified sequence rear left, front left,
front right, rear right.

To bleed the secondary circuit, the bleeding device remains connected to the brake fluid reservoir. Bleeding pressure is approx. 2.0 bar.

Throughout the entire bleeding process, the brake pedal must be operated cyclically (keep depressed for 2 to 3 seconds, then release slowly). After
operating the pedal for the last time, hold the brake pedal down and close the bleeder valve.

2. Bleed the brake system and adjust the brake-fluid level.
3. When replacing the hydraulic unit, code the control unit (manual transmission/Tiptronic).
4. Carry out the following tests:

^

Check the system for leaks.

Hydraulic Control Assembly - Antilock Brakes|Service and Repair|Page 2546 > < Hydraulic Control Assembly - Antilock Brakes|Service and Repair|Page 2544