Oxygen Sensor Heater Monitoring

For proper function of the Oxygen sensors, their ceramic elements must be heated. A non-functioning heater delays or prevents either the sensor
readiness (LSU) or the proper signal output (LSF1) for closed loop control and thus influences emissions.

Oxygen sensor upstream catalyst (LSU)

The heater control loop is integrated within the oxygen sensor hardware and has to achieve a target temperature of about 750 °C of the ceramic element.

By monitoring the power stage an electric fault of the heater line (short cut to UB, short cut to ground, broken line) will be detected.

Oxygen sensors downstream catalysts (LSF1)

For diagnostic of the sensor heater a specific current pulse is supplied via a load resistance and the voltage is measured. The intern resistance of the
sensor heater is calculated with the voltage deviation. The result will be compared with a reference map resistance, which considers aging and sampling
deviations. In case of internal resistance > map resistance the diagnosis stores a fault and the MIL will be illuminated.

By monitoring the power stage an electric fault of the heater line (short cut to UB, short cut to ground, broken line) will be detected.

Monitoring Structure (Oxygen sensor upstream catalyst)