3. If the triggering unit is new, lock the airbag triggering unit using the PIWIS Tester 9718.

Subsequent work

Subsequent work for triggering unit

1. If installed, install control unit for tilt sensor. Refer to Removing and installing control unit for tilt sensor
2. Connect battery. Refer to Work instructions after disconnecting the battery
3. Install centre console. Refer to Removing and installing centre console
4. Install centre console cover. Refer to Removing and installing centre console cover
5. Install left and right covers of console. Refer to Removing and installing centre console cover

Programming triggering unit

Triggering unit - reading out and writing in data

WARNING:  Sudden voltage interruption of the power supply to the control module.

-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery
charger with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

INFORMATION:

-

The PIWIS Tester 9718 instructions take precedence since the description may be different. This may be due to more recent software versions.

-

The procedure described here has been structured in general terms; different text or additions may appear in the PIWIS Tester 9718.

1. Connect the Porsche System Tester to the vehicle and start the System Tester. Switch on ignition. >> Continue.
2. Select vehicle type using the cursor keys.
3. Move from vehicle type to the list of control units. Locking is only possible after an automatic control unit search.
4. Select Posip with the cursor keys and press the >> key.
5. Select Control unit replacement with the cursor keys and press the >> key.
6. Select Read out values (codings) with the cursor keys and press >>.
7. The message Codes successfully read out appears on the screen of the Porsche System Tester. Press >>.
8. Switch off ignition and replace control unit.
9. Switch on ignition. Switch to the Special functions menu and perform the vehicle handover using the F8 key.

10. In the Special functions menu, erase All fault memories >>, compare Vehicle identification number and confirm.
11. With the cursor keys on Posip - Replacing control unit, after replacement of the control unit, the readout data (see Section 6) are installed under

the menu Write in data press >>.

12. System Tester displays Codes successfully written in. Press >>.
13. Locking is only possible after an automatic control unit search.

Lock triggering unit:

14. Change to the menu Posip - lock and press >>.
15. Select the country-specific Equipment and press >>.
16. Start Lock with F8.
17. Observe message on Tester.
18. Quit menu, carry out a test drive, and read out fault memory.

Coding triggering unit