Oxygen Sensor: Service Precautions

Precautionary Measures When Handling Oxygen Sensors

CAUTION: 
Improper handling of oxygen sensors.
-

Material damage
-

Do not remove the plastic cap on the thread until just prior to fitting the oxygen sensor. The thread grease must never come into
contact with the connector.

-

Protect sensors - before and after fitting - against mechanical shocks.

-

Sensors that were dropped on the floor must not be used owing to the risk of a broken ceramic insulator.

-

The cables must not be twisted or kinked when the sensors are screwed in. Avoid pulling on the cable and connector.

-

Cleanliness in the housing of the plug connections is of utmost importance for the oxygen sensor to function properly. Particles of dirt
can impair the function of the oxygen sensor. The connector must therefore be protected against any and all types of soiling.

-

Sensors with a soiled or damaged connector must no longer be used.   Protect the cables and plugs when carrying or moving the
exhaust system with the sensors already fitted.

-

High-pressure cleaning equipment must not be used in the area of the sensors and plug connections.

-

Contact and corrosion agents, e.g. Stabilant, must not be applied to the plug contacts of the oxygen sensors.