3. Pull off plug connection on residual pressure retaining valve (a/f 12) and screw on the filling unit adapter T10157/1 at the correct position on the

residual pressure retaining valve.

Note: 
^

The air-spring strut must only be filled with the approved gasses, dual-process gasses Argon and Corgon.

^

In isolated cases, up to 11 bar overpressure (upper tolerance, spring strut depressurized) is required to open the residual pressure retaining valve.

^

Fill the air-spring strut using several individual pressure shots. Filling the air with individual pressure shots will prevent the air-spring strut from
being filled with too much overpressure.

^

Do not fill the air-spring strut with overpressure of more than 4.5 bar.

^

The residual pressure retaining valve automatically reduces excessive overpressure to the minimum overpressure of approximately 3 bar.

4. Fit the - filling unit to the pressure gauge unit of the compressed air bottle.

5. Set the - pressure gauge unit (flow limiter) to approximately 20 l/min -arrow-.

6. Overcome the counter-pressure of the residual pressure retaining valve with several individual pressure shots and fill the air-spring strut. When