background image

5. Remove oxygen sensor from below at the exhaust manifold using a suitable tool. -1-

Installing oxygen sensor ahead of catalytic converter

Cylinder bank 1 to 4

1. Carefully coat the thread of the oxygen sensor with 000.043.207.07.

2. Carefully screw in oxygen sensor at the exhaust manifold by hand. -1- Screw on oxygen sensor correctly. Difficult to access with torque wrench.

Careful tightening by hand is acceptable. - Tightening torque: 45 Nm (33 ftlb.)±5 Nm (±3.5 ftlb.)

CAUTION:
The oxygen sensor cable can be damaged if twisted.
-

Change in emissions.

-

Check Engine light comes on.
-

Always expose oxygen sensor cable so that the wire can turn when unscrewing or screwing in the sensor.

-

Do not kink cable.

3. Route oxygen sensor cable around the exhaust manifold and generator and clip it in.