Page 12
background image

2. Connectors contained in the Repair kit for Cayenne harnesses NR.155-2 and can be replaced individually.

CAUTION:
Using plug-in contacts made of different materials
-

Oxidation of plug-in contacts
-

Only use the plug-in contacts listed in the wiring diagram for the corresponding plug connection. Always plug gold contacts together
with gold contacts.

-

The wiring diagrams can be displayed using the PIWIS Tester P 9718.

For repairing wire harnesses individual connectors are offered in a Repair kit for Cayenne harnesses NR.155-2. In this Repair kit for Cayenne
harnesses NR.155-2, connectors are contained primarily that are installed in crash and external areas.

The Repair kit for Cayenne harnesses NR.155-2 contains detailed descriptions about removing and installing individual plug-in contacts.

3. Connectors not contained in the Repair kit for Cayenne harnesses NR.155-2.

Connectors not contained in the Repair kit for Cayenne harnesses NR.155-2 can be ordered from the CARTOOL company.

The order must contain the following specifications.
3.1. Version 1 for identifying the required connector:

3.1.1. Legible specifications of the manufacturer on the connector, e.g., complete item number, number of pins, housing colour, and whether

pin or socket housing.

3.1.2. If the data mentioned in Version 1 is not legible, is incomplete, or not present, Version 2 is also possible for ordering.

3.2. Version 2 for identifying the required connector:

3.2.1. Vehicle type
3.2.2. Model year
3.2.3. PORSCHE part number
3.2.4. Which wire harness (e.g. main wire harness, wire harness for engine, etc.)
3.2.5. Specifications from the wiring diagram

b. Field
c. Component (for components with multiple connectors e.g. instrument cluster, please specify connector 1, 2, 3 etc.)
d. Connection point (e.g. X11, X12 etc.)

3.3. Version 3 for identifying the required connector:

3.3.1. Call up corresponding wiring diagram in PIWIS Tester P 9718.
3.3.2. Click on one of the plug-in contacts of the required connector with the mouse.

INFORMATION:  The specifications displayed are subject to a constant updating process. For this reason, it can happen that specifications are
incomplete or not available. If this is the case, use one of the other versions for ordering connectors if possible.

3.3.3. Note all displayed specifications for this connector and specify when ordering the connector.

3.4. If the data listed under Version 1 to Version 3 is included and complete, the CARTOOL company can identify the correct connector.
3.5. Ordering address:

CARTOOL company, GmbH
Strauáenlettenstr. 15
85053 Ingolstadt

Procedure for releasing connectors that are difficult to move

1. Pull connector off lid-release motor.

1.1. Release connector on motor for lid-release with suitable auxiliary materials (e.g. angled piece of wire with diameter of approx. 1mm) -a-

-arrow A- and pull off -arrow B-.
Engage wire at the release. Pulling on the wire in direction of arrow releases the connector and can be pulled off.