Fault code setting conditions

Fault codes can be set in several circumstances, e.g.:

-

when disconnecting battery

-

when disconnecting plug connections

-

when there is a power failure

In these circumstances, no fault is present in the system and the fault memory must be erased.

Fault memory Info key F8

In order to be able to assess the fault exactly, the fault memory Info key F8 must be pressed. This information should be saved using the Save key F4 and
printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased.

Fault type - Frequency counter/Temperature/Voltage; Speed/Time of occurence

Fault type
The following display types are available:

-

EEPROM fault

-

Tuner communication fault

-

General communication fault

Key code
The button which has caused the fault is displayed in plain text.

Frequency counter:
When a fault first occurs, a fault entry is made in the fault memory and the counter is simultaneously set to 50. If a fault is present, the counter is
incremented by 1 for each "ignition on". The maximum count is 100. The counter is decremented if the fault is no longer present. The fault memory is
erased automatically when the counter reaches 0.

First occurrence (month, day)
The date (month and day) on which the fault was first detected is displayed. Month and day.

Temperature - first occurrence
The value indicates the temperature (temperature sensor in the gateway) at the time the fault occurred. The temperature of the fibre optic transmitter is
monitored: max 85 °C.

Speed - first occurrence
The value indicates the vehicle speed at the time the fault occurred.

Supply voltage - first occurrence
The value indicates the voltage at the time the fault occurred.

Hourmeter - first occurrence
The value indicates the operating hours at the time the fault first occurred.

Last occurrence (month, day)
The date (month and day) on which the fault was last detected is displayed. Month and day.

Temperature - last occurrence
The value indicates the temperature (temperature sensor in the gateway) time the fault was last detected.

The temperature of the fibre optic transmitter (FOT) is monitored: max 85

Supply voltage - last occurrence
The value indicates the voltage at the time the fault last occurred.

Hourmeter - last occurrence
The value indicates the operating hours at the time the fault was last detected.

Identification

Identification

The diagnosis software number and the part number for the PCM2 can be read out under this menu item.