porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7793 > < Initial Inspection and Diagnostic Overview|Page 7791
Page 40
background image

Porsche System Tester II establishes a difference between the required and actual installed components list and there is no fault code in one of the fault
memories of the MOST control modules.

If there is a fault code present in one of the MOST control modules, the display '*' is only shown in the 'PCM2 MMI function selection' in front of the
line 'MOST required installed components list'.

If there is a display in the menu Control module, an existing fault code has priority and a '#' is set.

External Amplifier

External Amplifier

The external amplifier is optional with an external BOSE amplifier and is connected via the optical waveguide with the PCM2 or CRD23.

External BOSE Amplifier Actual Values

External BOSE Amplifier Actual Values

-

Blower speed, air-conditioning.

-

MOST unlock counter.

-

MOST transmission error.

-

Supply voltage.

Part 1

Initial Inspection and Diagnostic Overview|Page 7793 > < Initial Inspection and Diagnostic Overview|Page 7791