porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Campaign W575 - External Spare Tire Carrier Limit Switch|Page 1845 > < Campaign W575 - External Spare Tire Carrier Limit Switch
Page 2
background image

Time Allowance

Parts Info

Tools

Administrative Procedure: See Attachment "B"

Attachment "A":

Work Procedure

Deactivate limit switch for external spare wheel with the PIWIS Tester.

1.

Connect a charger with a rated current of at least 40 A to the power feed for the electrical system battery in the engine compartment and switch it
on.

Note

The PIWIS Tester instructions take precedence and in the event of a discrepancy these are the instructions that must be followed. A
discrepancy may arise with later software versions for example.

2.

Connect the PIWIS Tester with installed test software version 10.0/06/2005 (or higher) to the data link connector and switch it on. 

3.

Switch on ignition.

4.

Select "Cayenne" as the vehicle type in the PIWIS Tester main menu.

5.

Using the PIWIS Tester, select "Control unit search" under Control units in the main menu. If one or more faults are stored that do not relate to the
"limit stop for external spare wheel", the faults must be located and corrected using the PIWIS Tester in accordance with "Guided Fault Finding".
This work cannot be invoiced under workshop campaign number W575. After correcting the faults and erasing the fault memory, continue with

Campaign W575 - External Spare Tire Carrier Limit Switch|Page 1845 > < Campaign W575 - External Spare Tire Carrier Limit Switch