Cayenne S (9PA) V8-4.5L (2003)
2. Position the press-out and unlocking tools for tab and round plug connectors of all sizes NR.155 on the primary locking mechanism and lift the
locking mechanism.
3. Pull LWL, e.g., -B- carefully in the -direction of arrow-. If it is not possible to pull out the LWL, check again if the secondary locking is
completely released and if the primary locking is raised sufficiently.
Visual inspection of lockings, connector housing, and contacts for possible damage and if necessary, exchange the damaged parts.
Installing optical contacts on connector side
Remove the dust boot right before plugging.
Check the proper condition of the contacts.
1. Insert the optical contact -B- in the connector until it engages audibly.