All Technical Service Bulletins for PROM - Programmable Read Only Memory:|23/06 > < Engine Controls - Reduced Throttle Response
Page 2
background image

Tools:

PIWIS Tester 9718 with test software version 14.20/06/2006 (or higher), Part No. 000.721.971.WW.142

Work Procedure:

Program the DME control unit with the new software version.

CAUTION

A fault is entered in the fault memory and control unit programming is aborted due to low voltage.

-

Increased current draw during diagnosis or control unit programming can cause a drop in voltage, which can result in one or more fault entries and
the abnormal termination of the programming process.

-

Before commencing work, connect a suitable battery charger with a current rating of at least 40 A to the jump-start terminals in the engine
compartment.

1

Connect the PIWIS Tester with installed test software version 14.20/06/2006 (or higher) to the vehicle and switch it on.

2

Switch on ignition.

3

Call up the Diagnosis menu and select the vehicle type Cayenne.

4

Using the PIWIS Tester, activate the control unit search in the Control units menu. If faults are stored in the fault memory, these must first be
located and corrected.

5

Programming the DME control unit.

INFORMATION

-

After starting the program and when the PIWIS software version 14.2 or 15.0 is used, the tester display shows the message "Data records in the
vehicle and in the Tester are identical; flashing is unnecessary". Ignore this message and continue the control unit programming procedure with
F12.

-

The reason for this is a software error which has been rectified as of PIWIS software version 16.0 (available from the end of CW 38/06).

References:

-->Workshop Manual '24701900 Removing and installing DME control unit - section on "Programming"'.

Disclaimer