porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Porsche Cayenne Turbo (9PA) V8-4.8L Turbo (2008)|Capacity Specifications|Page 974 > < Porsche Cayenne Turbo (9PA) V8-4.8L Turbo (2008)|Capacity Specifications|Page 972
Page 7
background image

3. Connect the vacuum pressure gauge of the bleeder tool to the flexible extension. When doing so, ensure that both shutoff valves are closed

(positioned at 90 degrees with respect to flow direction).

4. Connect the Venturi nozzle to the vacuum pressure gauge.

Connecting Venturi nozzle to vacuum pressure gauge

Information

The coolant amount provided must be approx. 2 liters more than the amount to be filled in.
Because differing quantities of coolant can drain away for different types of repairs, the filling capacities can vary greatly. Recommendation: To
be on the safe side, fill the canister to 30 l, then bleed the cooling system. The difference after bleeding is the coolant quantity that was sucked in.
Observe volume scale on the canister.
An antifreeze content of -35 degrees C corresponds to a mixture of 50 : 50 (antifreeze: water).

5. Place a canister with a sufficient amount of coolant and with an antifreeze content of -35 degrees C beside the vehicle close to the reservoir.

Information

The bleeding process is completed more quickly if the canister is positioned at roughly the same height as the coolant expansion tank.

6. Push the filler hose -5- of the vacuum pressure gauge onto the canister connection. Lay the return line -6- from the Venturi nozzle to a second

container (bucket).

Components of vacuum filling device

Information

A hissing sound after connecting the compressed air supply is usual.

7. Connect the compressed air supply.

Porsche Cayenne Turbo (9PA) V8-4.8L Turbo (2008)|Capacity Specifications|Page 974 > < Porsche Cayenne Turbo (9PA) V8-4.8L Turbo (2008)|Capacity Specifications|Page 972