porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Catalytic Converter|Description and Operation|Page 2253 > < Variable Valve Timing Actuator|Service and Repair|Page 2248
Page 1
background image

Catalytic Converter: Description and Operation

Diagnostic Overview

The diagnostic function which is used for monitoring of the catalyst efficiency is based on measure of the oxygen within the catalyst determined by the
upstream and the downstream oxygen sensor. If all monitoring conditions are fulfilled, then a special defined A/F-modulation will be done. The relation
of the deviations between the current downstream-sensor-signal to the average value of the downstream-sensor-signal is a sign for catalyst condition. The
catalyst system is considered malfunctioning, if after a specified number of monitoring cycles the average of the ratios exceeds a threshold. The
corresponding fault code is stored.

General description

The first lean to rich cycle is only used to establish an average voltage value of the downstream sensor voltage. During subsequent lambda controller
cycles the oxygen storage capacity (OSC) is based on the integrated (accumulated) value of the difference between the average value of the previous lean
to rich cycle and the measured instantaneous voltage during the current lean to rich cycle. This surface integral will be normalized, weighted and
corrected and is a measure of the catalyst efficiency. The catalyst system is considered malfunctioning, if after a specified number of monitoring cycles
the average of the single efficiency values exceeds a threshold. The corresponding fault code is stored.

Flowchart

Variables List

Catalytic Converter|Description and Operation|Page 2253 > < Variable Valve Timing Actuator|Service and Repair|Page 2248