Cayenne Turbo (9PA) V8-4.8L Turbo (2008)
15. If there is a leak, gently sashaying, moving and growing air bubbles will emerge (union nut on injector is shown). These could be caused by a
damaged seal, loose connections or incorrectly fitted union nuts, for example. The cause must be determined and corrected.
Subsequent work
1. Remove tool setup.
2. Fit fuel line. To do this, fit fuel supply line (low pressure) onto marking correctly. Counter while doing this. - Tightening torque: 35 Nm (26 ftlb.)
3. Fit engine cover.
4. Fit fuses or connect battery.
5. Bleed the fuel high-pressure system.