Cayenne Turbo (9PA) V8-4.8L Turbo (2008)
9. Unclip line -1- on generator -arrow-.
10. Loosen supply connection piece on generator.
10.1. Unscrew fastening screw -2- on the supply connection piece -1-.
10.2. Remove supply connection piece -1- from the generator -arrow-.
11. Remove heat shield for generator lines.
11.1. Unclip electric lines for the generator and oxygen sensor at the heat shield -1- ( -arrows A- ).
11.2. Unscrew fastening screw -2-.
11.3. Open the retaining clip -3- ( -arrow B- ) and remove the B+ line -4- ( -arrow C- ).