Cayman (987) F6-2.9L (2009)
-
When loosening or tightening the refrigerant lines with line connections, always counter with the special tool assembly tool 9822 if possible.
-
When loosening or tightening the refrigerant lines with connections to air-conditioning components (e.g. condenser), always counter with a size 21
open-ended wrench if possible.
-
Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.
-
Wet the O-rings of the refrigerant lines with refrigerant oil.
-
Do not open the plugs for the lines and connections until shortly before installation.
-
Close off all lines and connections using suitable plugs during removal.
3. Carefully insert the refrigerant lines into the condenser and secure with the fastening screws -2-. - Tightening torque: 14 Nm (10.5 ftlb.)
4. Engage air guide on condenser -A- and screw down using the two fastening screws -1-. - Tightening torque: 4 Nm (3 ftlb.)