Cayman (987) F6-2.9L (2009)
1. Unscrew the two fastening screws -1- holding the air guide for the condenser.
2. Pull the air guide forward and disengage it at the condenser -A-.
3. Unscrew the fastening nuts for both holders line, open the holder and take out the line.
INFORMATION:
-
Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.
-
Wet the O-rings of the refrigerant lines with refrigerant oil.
-
Do not open the plugs for the lines and connections until shortly before installation.
-
Close off all lines and connections using suitable plugs during removal.
4. Unscrew the fastening screws -1- of the line condenser-condenser and pull the line out of both condensers.
Installing the condenser-condenser line
INFORMATION:
-
When loosening or tightening the refrigerant lines with line connections, always counter with the special tool assembly tool 9822 if possible.
-
When loosening or tightening the refrigerant lines with connections to air-conditioning components (e.g. condenser), always counter with a size 21
open-ended wrench if possible.
-
Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.
-
Wet the O-rings of the refrigerant lines with refrigerant oil.
-
Do not open the plugs for the lines and connections until shortly before installation.
-
Close off all lines and connections using suitable plugs during removal.
1. Carefully push the lines into the condensers and screw tight with the fastening screws. - Tightening torque: 14 Nm (10.5 ftlb.)