Headlamp Switch > < Removing and Installing Rear Angle Sensor For Headlight Levelling System|Page 5746
Page 2
background image

INFORMATION:  If the angle sensor has been replaced, the front end control unit must be calibrated; afterwards the headlight setting must be
checked and adjusted if necessary.

1. Fasten angle sensor to retaining bracket and secure with fastening screw -3- to the side member.

2. Engage electrical plug connection and pull rubber cover -1- carefully over the plug connection (protects against ingress of water).
3. Engage intermediate link on rotary lever and secure with fastening nut -2-. - Tightening torque: 7 Nm (5 ftlb.)

Subsequent work

Subsequent work - front angle sensor for headlight levelling system

INFORMATION:  If the angle sensor has been replaced, the front end control unit must be calibrated; afterwards the headlight setting must be
checked and adjusted if necessary.

1. Install front underbody panel.
2. Connect the Porsche System Tester PIWIS Tester 9718 to the vehicle and start the System Tester. Switch on ignition. >> to continue.
3. Select front end on the control unit, carry out calibration menu.
4. Check headlight setting and adjust if necessary.