renault Workshop Repair Guides

Renault Workshop Service and Repair Manuals

Blower Motor Relay > < Blower Motor|Diagrams
Page 1
background image

Blower Motor: Service and Repair

Fig. 8 Plenum cover panel removal.

1.

Disconnect battery ground cable.

2.

On 1984 models, remove ignition coil.

3.

On all models, remove plenum panel seal (3), plenum cover attaching screws (1) and the cover panel, Fig. 8.

4.

Remove 3 blower housing nuts.

5.

Disconnect electrical connectors from motor and blower resistor.

6.

Lift blower motor and housing assembly from vehicle.

7.

Reverse procedure to install.

Blower Motor Relay > < Blower Motor|Diagrams