Alarm Module: Programming and Relearning

PROCEDURE

FUNCTION SETTING (ECM CUSTOMIZING)

Connect the Vehicle Diagnostic Interface to data link connector.
Turn the ignition switch to ON.
On the <<Main Menu>> display screen, select the {Each System Check}.
On the <<System Selection Menu>> display screen, select the {Keyless Unit Mode}.
On the <<Keyless Unit Mode>> display screen, select the {Customizing}.
Select the item with UP/DOWN key, change the setting with LEFT/RIGHT key and press the [YES] key.

List of function setting item (ECM customizing)

IMPORTANT:

-

It is possible to control the original functions of vehicle when settings above are corresponded to vehicle equipment.

-

Do not change the settings except for setting above during operation of equipment setting.

-

Resetting is needed if installing a new keyless unit.

-

In passive mode, the system will automatically activate the alarm but WILL NOT automatically lock the doors. Failure to lock the doors
manually will result in a higher security risk.

NOTE:

-

For details concerning operation procedure, refer to the Vehicle Diagnostic Interface OPERATION MANUAL.

-

Set the No.3 and No.4 items above when installing impact sensor (OP).

Turn the ignition switch to OFF, and then remove the Vehicle Diagnostic Interface.

ALARM HISTORY REPORT MODE

Turn the ignition switch to ON.
Security indicator light blinks.