9-2X F4-2.5L (2006)
Variable Valve Timing Pressure Switch: Service and Repair
Oil Pressure Switch
REMOVAL
1. Disconnect the ground cable from battery.
2. Remove the air intake chamber.
3. Remove the engine harness connector from bracket.
4. Disconnect the connector from variable valve lift diagnosis oil pressure switch.
5. Remove the variable valve lift diagnosis oil pressure switch.
^
LH side
^
RH side
INSTALLATION
Install in the reverse order of removal.
NOTE: Apply liquid gasket to the thread of variable valve lift diagnosis oil pressure switch.
Liquid gasket: THREE BOND 1324 (Part No. 004403042) or equivalent
Tightening torque: 17 Nm (1.7 kgf-m, 12.5 ft. lbs.)