saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Relay Box|Specifications|Page 1017 > < Relay, +54 (21)|Page 1013
Page 1
background image

Relay Box: Specifications

Measurement Value, REC (701)

Scope

Directions for the measurement of levels and signals at the REC and the measurement values are given on the following information.

NOTE:  When measuring values at the pins the connector must remain plugged into the electrical centre. The pins can be accessed by lifting up the
protective cover on the connector.

Remember:

-

Pay attention to the measurement requirements, use common sense when judging the measurement result.

-

Check first that there is a voltage supply to the control module and that it is grounded.

-

Then check all sensor inputs and signals from other systems.

-

Lastly check the outputs of the control module. Remember that the output values do not say anything about the functioning of the related actuator.

-

If any measurement value is incorrect, use the wiring diagram to determine which cables, connectors or components should also be checked.

-

The given measurement values are as measured with a calibrated Fluke 88/97.

-

The measurement values %(+) and ms(+) show respectively the pulse ratio and the pulse length. A test instrument with pulse ratio and pulse width
measurement must be used. The plus sign (+) denotes a positive trigger pulse, TRIG+.

Connector Body 1 to main wiring harness

Relay Box|Specifications|Page 1017 > < Relay, +54 (21)|Page 1013