saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Grounding Point|Locations|Page 10006 > < Engine Bay Electrical Centre 342 (UEC)|Page 10002
Page 1
background image

Grounding Point: Locations

Grounding Points

General

There are two main types of grounding point in the car: those that are equipped with a component number, and those where the component is grounded
directly on to the chassis (e.g., temperature sensors, oil pressure sensors, etc.).

This section deals with those grounding points that have a component number.

The grounding points to which a component is connected can differ depending on whether the car is a left-hand or right-hand-drive model. This can be
seen in the system diagrams.

Cables are sometimes collected in a crimp connection immediately before a grounding point. These connections will be found in the list of grounding
points.

The car battery is grounded via two cables. One of the cables has a cross sectional area of 25 sq.mm and is connected directly to the LH engine
mounting (grounding point G25).

The other has a cross sectional area of 16 sq.mm and is connected to grounding point G2, which is located on the side of the LH structural member by
the connector bracket.

The following connections between the grounding points are not are not shown on the circuit diagrams:

1. There is a redundant ground between the engine/gearbox and one of the wheel arches.
2. Grounding point G30A is connected to grounding point G30B via crimp J1, the engine bay electrical centre 342 and crimp J2.
3. Grounding point G3 is connected to grounding point G29 via the rear electrical centre 701.
4. Grounding point G34S is connected to grounding point G43 via crimps J108 and J80

Grounding points

Grounding Point|Locations|Page 10006 > < Engine Bay Electrical Centre 342 (UEC)|Page 10002