Under certain conditions between measured voltage and conductance, the analyzer will need to know if the test is being performed before or after
recharging the battery in order to correctly assess the battery.

IMPORTANT:  Make a practice of checking the battery acid level before each battery check. This is especially important in warm climates.

Once any questions have been answered, the analyzer will display the test results in one of the following ways:
Message    Signification
GOOD BATTERY    Fully charged. No action
GOOD-CHARGE    Charge the battery, connect and use
CHARGE & TEST    Charge the battery and repeat the test. If the message returns after charging - replace the battery
CHANGE BATTERY    Replace the battery
BAD CELL CHANGE    Replace the battery
When "GOOD BATTERY" and "GOOD-CHARGE" are shown, the display will switch between showing the message and showing the battery
charge in steps of 25%, e.g. "CHARGE STATUS: 0-25%". This value provides a good indication of the current battery status.
We recommend performing an extra test with the battery outside the car when the analyzer indicates that the battery should be replaced within the
warranty period. The test code from this test must then be attached to the warranty claim (see Warranty Policy for further information).

IMPORTANT:  Check also the replacement battery with Battery Analyzer 311 before fitting in the car. If the replacement battery cold starting
current is not specified to SAE standard, select the DIN standard test in step 7 above.