saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

System Overview|Page 7493 > < System Overview|Page 7491
Page 27
background image

The SID unit receives information on headlamp functionality from the filament monitor. The SID unit sends B+ to the filament monitor via pin 10. If a
headlamp bulb is faulty, the filament monitor output will be grounded.

The SID unit uses the information for a CHECK message (3 second delay).

Diagnostics

If a short-circuit to ground occurs in the filament monitor circuit, the CHECK message for a faulty lamp will be shown even though the lamp is OK.

In the event of an open circuit, the CHECK message will not be shown even if one of the lamps is faulty.

Rheostat

Rheostat