9-3 FWD (9440) L4-2.0L Turbo (B207R) (2009)
OFF = 0V, ON = B+
Winding resistance in solenoid S1 is rated 12-16 ohms at 20 °C
Winding resistance in solenoids S2-S5 is rated 11-15 ohms at 20 °C
Diagnostics:
In case of a fault in solenoid S1 fault code P0773 will be generated and the transmission will go into limp-home mode
In case of a fault in solenoid S2 fault code P0753 will be generated and the transmission will go into limp-home mode
In case of a fault in solenoid S3 fault code P0758 will be generated and the transmission will go into limp-home mode
In case of a fault in solenoid S4 fault code P0763 will be generated and the transmission will go into limp-home mode
In case of a fault in solenoid S5 fault code P0768 will be generated and the transmission will go into limp-home mode
Solenoid Valves SLS, TCM FA 57 (531)
Solenoid Valves SLS, TCM FA 57 (531)
Location
Solenoid valves, TCM (531)