Information Bus: Symptom Related Diagnostic Procedures

Diagnostic Tool's Screen Does Not Go On

The Diagnostic Tool's Screen Does Not Go On When The ON Button Is Pressed.

Fault symptoms

The diagnostic tool's screen does not go on when the ON button is pressed. No system can be contacted.

Conditions

The following conditions are applicable:

-

Battery OK.

Diagnostic help

First check that no slide-out of the data link connector pins for current supply (+30 circuit) and ground has occurred. Then use a test lamp to check
whether any lead and/or fuse supplying the data link connector with current is faulty.

Following this, check whether the diagnostic tool works on another car.

If no fault can be found, decide whether to repair or replace the diagnostic tool.